Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Clin Chem ; 70(3): 528-537, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38431279

RESUMEN

BACKGROUND: Lipid profiling is central for coronary artery disease (CAD) risk assessment. Nonadherence or unreported use of lipid-lowering drugs, particularly statins, can significantly complicate the association between lipid profile measures and CAD clinical outcomes. By combining medication history evaluation with statin analysis in plasma, we determined the effects of inaccurately reported statin use on lipid profile measures and their association with CAD risk. METHODS: We compared medication history of statin use with statin concentration measurements, by liquid chromatography-tandem mass spectrometry, in 690 participants undergoing coronary angiography (63 ± 11 years of age). Nominal logistic regression was employed to model CAD diagnosis with statin measurements, phenotypic, and lipid profile characteristics. RESULTS: Medication history of statin use was confirmed by statin assay for 81% of the patients. Surprisingly, statins were detected in 46% of patients without statin use records. Nonreported statin use was disproportionately higher among older participants. Stratifying samples by statin history resulted in underestimated LDL-lipid measures. Apolipoprotein B concentrations had a significant inverse CAD association, which became nonsignificant upon re-stratification using the statin assay data. CONCLUSIONS: Our study uncovered prominent discrepancies between medication records and actual statin use measured by mass spectrometry. We showed that inaccurate statin use assessments may lead to overestimation and underestimation of LDL levels in statin user and nonuser categories, exaggerating the reverse epidemiology association between LDL levels and CAD diagnosis. Combining medication history and quantitative statin assay data can significantly improve the design, analysis, and interpretation of clinical and epidemiological studies.


Asunto(s)
Enfermedad de la Arteria Coronaria , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Lípidos , Medición de Riesgo , Factores de Riesgo , Persona de Mediana Edad , Anciano
2.
Int J Mol Sci ; 24(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37175638

RESUMEN

Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 µL of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Ácidos Fíbricos/uso terapéutico , Cromatografía Liquida , Espectrometría de Masas en Tándem , Atorvastatina/uso terapéutico , Biomarcadores
3.
Alzheimers Dement ; 19(2): 391-404, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35416404

RESUMEN

We propose the hypothesis that small high-density lipoprotein (HDL) particles reduce the risk of Alzheimer's disease (AD) by virtue of their capacity to exchange lipids, affecting neuronal membrane composition and vascular and synaptic functions. Concentrations of small HDLs in cerebrospinal fluid (CSF) and plasma were measured in 180 individuals ≥60 years of age using ion mobility methodology. Small HDL concentrations in CSF were positively associated with performance in three domains of cognitive function independent of apolipoprotein E (APOE) ε4 status, age, sex, and years of education. Moreover, there was a significant correlation between levels of small HDLs in CSF and plasma. Further studies will be aimed at determining whether specific components of small HDL exchange across the blood, brain, and CSF barriers, and developing approaches to exploit small HDLs for therapeutic purposes.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Enfermedad de Alzheimer/líquido cefalorraquídeo , Apolipoproteínas E , Apolipoproteína E4 , Encéfalo , Cognición , Péptidos beta-Amiloides/líquido cefalorraquídeo
4.
Biomolecules ; 12(10)2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-36291648

RESUMEN

Aberrations in lipid and lipoprotein metabolic pathways can lead to numerous diseases, including cardiovascular disease, diabetes, neurological disorders, and cancer. The integration of quantitative lipid and lipoprotein profiling of human plasma may provide a powerful approach to inform early disease diagnosis and prevention. In this study, we leveraged data-driven quantitative targeted lipidomics and proteomics to identify specific molecular changes associated with different metabolic risk categories, including hyperlipidemic, hypercholesterolemic, hypertriglyceridemic, hyperglycemic, and normolipidemic conditions. Based on the quantitative characterization of serum samples from 146 individuals, we have determined individual lipid species and proteins that were significantly up- or down-regulated relative to the normolipidemic group. Then, we established protein-lipid topological networks for each metabolic category and linked dysregulated proteins and lipids with defined metabolic pathways. To evaluate the differentiating power of integrated lipidomics and proteomics data, we have built an artificial neural network model that simultaneously and accurately categorized the samples from each metabolic risk category based on the determined lipidomics and proteomics profiles. Together, our findings provide new insights into molecular changes associated with metabolic risk conditions, suggest new condition-specific associations between apolipoproteins and lipids, and may inform new biomarker discovery in lipid metabolism-associated disorders.


Asunto(s)
Trastornos del Metabolismo de los Lípidos , Lipidómica , Humanos , Proteómica , Metabolismo de los Lípidos , Lípidos , Biomarcadores/metabolismo
5.
PLoS One ; 17(10): e0276649, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36279295

RESUMEN

BACKGROUND: Genetic variants in apolipoprotein L1 (APOL1), a protein that protects humans from infection with African trypanosomes, explain a substantial proportion of the excess risk of chronic kidney disease affecting individuals with sub-Saharan ancestry. The mechanisms by which risk variants damage kidney cells remain incompletely understood. In preclinical models, APOL1 expressed in podocytes can lead to significant kidney injury. In humans, studies in kidney transplant suggest that the effects of APOL1 variants are predominantly driven by donor genotype. Less attention has been paid to a possible role for circulating APOL1 in kidney injury. METHODS: Using liquid chromatography-tandem mass spectrometry, the concentrations of APOL1 were measured in plasma and urine from participants in the Seattle Kidney Study. Asymmetric flow field-flow fractionation was used to evaluate the size of APOL1-containing lipoprotein particles in plasma. Transgenic mice that express wild-type or risk variant APOL1 from an albumin promoter were treated to cause kidney injury and evaluated for renal disease and pathology. RESULTS: In human participants, urine concentrations of APOL1 were correlated with plasma concentrations and reduced kidney function. Risk variant APOL1 was enriched in larger particles. In mice, circulating risk variant APOL1-G1 promoted kidney damage and reduced podocyte density without renal expression of APOL1. CONCLUSIONS: These results suggest that plasma APOL1 is dynamic and contributes to the progression of kidney disease in humans, which may have implications for treatment of APOL1-associated kidney disease and for kidney transplantation.


Asunto(s)
Apolipoproteína L1 , Insuficiencia Renal Crónica , Humanos , Ratones , Animales , Apolipoproteína L1/genética , Apolipoproteína L1/metabolismo , Apolipoproteínas/genética , Riñón/patología , Insuficiencia Renal Crónica/genética , Insuficiencia Renal Crónica/patología , Ratones Transgénicos , Modelos Animales de Enfermedad , Albúminas
6.
Alzheimers Res Ther ; 14(1): 87, 2022 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-35751102

RESUMEN

BACKGROUND: Inducing brain ATP-binding cassette 1 (ABCA1) activity in Alzheimer's disease (AD) mouse models is associated with improvement in AD pathology. The purpose of this study was to investigate the effects of the ABCA1 agonist peptide CS-6253 on amyloid-ß peptides (Aß) and lipoproteins in plasma and cerebrospinal fluid (CSF) of cynomolgus monkeys, a species with amyloid and lipoprotein metabolism similar to humans. METHODS: CS-6253 peptide was injected intravenously into cynomolgus monkeys at various doses in three different studies. Plasma and CSF samples were collected at several time points before and after treatment. Levels of cholesterol, triglyceride (TG), lipoprotein particles, apolipoproteins, and Aß were measured using ELISA, ion-mobility analysis, and asymmetric-flow field-flow fractionation (AF4). The relationship between the change in levels of these biomarkers was analyzed using multiple linear regression models and linear mixed-effects models. RESULTS: Following CS-6253 intravenous injection, within minutes, small plasma high-density lipoprotein (HDL) particles were increased. In two independent experiments, plasma TG, apolipoprotein E (apoE), and Aß42/40 ratio were transiently increased following CS-6253 intravenous injection. This change was associated with a non-significant decrease in CSF Aß42. Both plasma total cholesterol and HDL-cholesterol levels were reduced following treatment. AF4 fractionation revealed that CS-6253 treatment displaced apoE from HDL to intermediate-density- and low density-lipoprotein (IDL/LDL)-sized particles in plasma. In contrast to plasma, CS-6253 had no effect on the assessed CSF apolipoproteins or lipids. CONCLUSIONS: Treatment with the ABCA1 agonist CS-6253 appears to favor Aß clearance from the brain.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Transportador 1 de Casete de Unión a ATP , Enfermedad de Alzheimer/líquido cefalorraquídeo , Péptidos beta-Amiloides/líquido cefalorraquídeo , Animales , Apolipoproteínas/metabolismo , Apolipoproteínas E/metabolismo , Colesterol , Humanos , Macaca fascicularis/metabolismo , Ratones , Péptidos
7.
J Mass Spectrom Adv Clin Lab ; 22: 34-42, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34939053

RESUMEN

Large epidemiological studies often require sample transportation and storage, presenting unique considerations when applying advanced lipidomics techniques. The goal of this study was to acquire lipidomics data on plasma and serum samples stored at potential preanalytical conditions (e.g., thawing, extracting, evaporating), systematically monitoring lipid species for a period of one month. Split aliquots of 10 plasma samples and 10 serum samples from healthy individuals were kept in three temperature-related environments: refrigerator, laboratory benchtop, or heated incubator. Samples were analyzed at six different time points over 28 days using a Bligh & Dyer lipid extraction protocol followed by direct infusion into a lipidomics platform using differential mobility with tandem mass spectrometry. The observed concentration changes over time were evaluated relative to method and inter-individual biological variability. In addition, to evaluate the effect of lipase enzyme levels on concentration changes during storage, we compared corresponding fasting and post-prandial plasma samples collected from 5 individuals. Based on our data, a series of low abundance free fatty acid (FFA), diacylglycerol (DAG), and cholesteryl ester (CE) species were identified as potential analytical markers for degradation. These FFA and DAG species are typically produced by endogenous lipases from numerous triacylglycerols (TAGs), and certain high abundance phosphatidylcholines (PCs). The low concentration CEs, which appeared to increase several fold, were likely mass-isobars from oxidation of other high concentration CEs. Although the concentration changes of the high abundant TAG, PC, and CE precursors remained within method variability, the concentration trends of FFA, DAG, and oxidized CE products should be systematically monitored over time to inform analysts about possible pre-analytical biases due to degradation in the study sample sets.

8.
J Lipid Res ; 62: 100099, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34324889

RESUMEN

Human high-density lipoproteins (HDLs) are a complex mixture of structurally related nanoparticles that perform distinct physiological functions. We previously showed that human HDL containing apolipoprotein A-I (APOA1) but not apolipoprotein A-II (APOA2), designated LpA-I, is composed primarily of two discretely sized populations. Here, we isolated these particles directly from human plasma by antibody affinity chromatography, separated them by high-resolution size-exclusion chromatography and performed a deep molecular characterization of each species. The large and small LpA-I populations were spherical with mean diameters of 109 Å and 91 Å, respectively. Unexpectedly, isotope dilution MS/MS with [15N]-APOA1 in concert with quantitation of particle concentration by calibrated ion mobility analysis demonstrated that the large particles contained fewer APOA1 molecules than the small particles; the stoichiometries were 3.0 and 3.7 molecules of APOA1 per particle, respectively. MS/MS experiments showed that the protein cargo of large LpA-I particles was more diverse. Human HDL and isolated particles containing both APOA1 and APOA2 exhibit a much wider range and variation of particle sizes than LpA-I, indicating that APOA2 is likely the major contributor to HDL size heterogeneity. We propose a ratchet model based on the trefoil structure of APOA1 whereby the helical cage maintaining particle structure has two "settings"-large and small-that accounts for these findings. This understanding of the determinants of HDL particle size and protein cargo distribution serves as a basis for determining the roles of HDL subpopulations in metabolism and disease states.


Asunto(s)
Apolipoproteína A-II/química , Apolipoproteína A-I/química , HDL-Colesterol/química , Tamaño de la Partícula
9.
J Lipid Res ; 61(3): 306-315, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31953305

RESUMEN

The composition-function relationship of HDL particles and its effects on the mechanisms driving coronary heart disease (CHD) is poorly understood. We tested the hypothesis that the functionality of HDL particles is significantly influenced by their lipid composition. Using a novel 3D-separation method, we isolated five different-sized HDL subpopulations from CHD patients who had low preß-1 functionality (low-F) (ABCA1-dependent cholesterol-efflux normalized for preß-1 concentration) and controls who had either low-F or high preß-1 functionality (high-F). Molecular numbers of apoA-I, apoA-II, and eight major lipid classes were determined in each subpopulation by LC-MS. The average number of lipid molecules decreased from 422 in the large spherical α-1 particles to 57 in the small discoid preß-1 particles. With decreasing particle size, the relative concentration of free cholesterol (FC) decreased in α-mobility but not in preß-1 particles. Preß-1 particles contained more lipids than predicted; 30% of which were neutral lipids (cholesteryl ester and triglyceride), indicating that these particles were mainly remodeled from larger particles not newly synthesized. There were significant correlations between HDL-particle functionality and the concentrations of several lipids. Unexpectedly, the phospholipid:FC ratio was significantly correlated with large-HDL-particle functionality but not with preß-1 functionality. There was significant positive correlation between particle functionality and total lipids in high-F controls, indicating that the lipid-binding capacity of apoA-I plays a major role in the cholesterol efflux capacity of HDL particles. Functionality and lipid composition of HDL particles are significantly correlated and probably both are influenced by the lipid-binding capacity of apoA-I.


Asunto(s)
Enfermedad Coronaria/sangre , Gotas Lipídicas/química , Lipoproteínas HDL/sangre , Adulto , Anciano , Enfermedad Coronaria/metabolismo , Femenino , Humanos , Gotas Lipídicas/metabolismo , Lipoproteínas HDL/metabolismo , Masculino , Persona de Mediana Edad , Tamaño de la Partícula , Adulto Joven
11.
N Engl J Med ; 382(8): 697-705, 2020 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-31860793

RESUMEN

BACKGROUND: The causative agents for the current national outbreak of electronic-cigarette, or vaping, product use-associated lung injury (EVALI) have not been established. Detection of toxicants in bronchoalveolar-lavage (BAL) fluid from patients with EVALI can provide direct information on exposure within the lung. METHODS: BAL fluids were collected from 51 patients with EVALI in 16 states and from 99 healthy participants who were part of an ongoing study of smoking involving nonsmokers, exclusive users of e-cigarettes or vaping products, and exclusive cigarette smokers that was initiated in 2015. Using the BAL fluid, we performed isotope dilution mass spectrometry to measure several priority toxicants: vitamin E acetate, plant oils, medium-chain triglyceride oil, coconut oil, petroleum distillates, and diluent terpenes. RESULTS: State and local health departments assigned EVALI case status as confirmed for 25 patients and as probable for 26 patients. Vitamin E acetate was identified in BAL fluid obtained from 48 of 51 case patients (94%) in 16 states but not in such fluid obtained from the healthy comparator group. No other priority toxicants were found in BAL fluid from the case patients or the comparator group, except for coconut oil and limonene, which were found in 1 patient each. Among the case patients for whom laboratory or epidemiologic data were available, 47 of 50 (94%) had detectable tetrahydrocannabinol (THC) or its metabolites in BAL fluid or had reported vaping THC products in the 90 days before the onset of illness. Nicotine or its metabolites were detected in 30 of 47 of the case patients (64%). CONCLUSIONS: Vitamin E acetate was associated with EVALI in a convenience sample of 51 patients in 16 states across the United States. (Funded by the National Cancer Institute and others.).


Asunto(s)
Lesión Pulmonar Aguda/patología , Líquido del Lavado Bronquioalveolar/química , Sistemas Electrónicos de Liberación de Nicotina , Vapeo/efectos adversos , Vitamina E/análisis , Lesión Pulmonar Aguda/etiología , Adolescente , Adulto , Anciano , Fumar Cigarrillos , Aceite de Coco/análisis , Femenino , Humanos , Limoneno/análisis , Masculino , Persona de Mediana Edad , Estados Unidos , Adulto Joven
12.
MMWR Morb Mortal Wkly Rep ; 68(45): 1040-1041, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-31725707

RESUMEN

CDC, the Food and Drug Administration (FDA), state and local health departments, and multiple public health and clinical partners are investigating a national outbreak of e-cigarette, or vaping, product use-associated lung injury (EVALI). Based on data collected as of October 15, 2019, 86% of 867 EVALI patients reported using tetrahydrocannabinol (THC)-containing products in the 3 months preceding symptom onset (1). Analyses of THC-containing product samples by FDA and state public health laboratories have identified potentially harmful constituents in these products, such as vitamin E acetate, medium chain triglyceride oil (MCT oil), and other lipids (2,3) (personal communication, D.T. Heitkemper, FDA Forensic Chemistry Center, November 2019). Vitamin E acetate, in particular, might be used as an additive in the production of e-cigarette, or vaping, products; it also can be used as a thickening agent in THC products (4). Inhalation of vitamin E acetate might impair lung function (5-7).


Asunto(s)
Líquido del Lavado Bronquioalveolar/química , Brotes de Enfermedades , Lesión Pulmonar/epidemiología , Vapeo/efectos adversos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos/epidemiología , Adulto Joven
13.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1118-1119: 137-147, 2019 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-31035135

RESUMEN

Progress toward better diagnosis and treatment of lipid metabolism-related diseases requires high throughput approaches for multiplexed quantitative analysis of structurally diverse lipids, including phospholipids (PLs). This work demonstrates a simplified "one-pot" phospholipid extraction protocol, as an alternative to conventional liquid-liquid extraction. Performed in a 96-well format, the extraction was coupled with high throughput UPLC and multiplexed tandem mass spectrometry (MS/MS) detection, allowing non-targeted quantification of phosphatidylcholines (PC), sphingomyelins (SM), lysophosphatidylcholines (LPC), phosphatidylethanolamines (PE), and phosphatidylinositols (PI). Using 50 µL aliquots of serum samples from 110 individuals, lipoproteins were fractionated by size, and analyzed for phospholipids and non-polar lipids including free cholesterol (FC), cholesteryl esters (CEs) and triglycerides (TGs). Analysis of serum samples with wide range of Total-TG levels showed significant differences in PL composition. The correlations of molar ratios in lipoprotein size fractions, SM/PL with FC/PL, PE/PL with TG/CE, and PE/PL with PI/PL, demonstrate the applicability of the method for quantitative composition analysis of high, low and very-low density lipoproteins (HDL, LDL and VLDL), and characterization of lipid metabolism related disease states.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Dislipidemias/sangre , Dislipidemias/diagnóstico , Fosfolípidos/sangre , Espectrometría de Masas en Tándem/métodos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Fosfolípidos/aislamiento & purificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Anal Bioanal Chem ; 411(12): 2493-2509, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30911800

RESUMEN

Inhalation of Bacillus anthracis spores can cause a rapidly progressing fatal infection. B. anthracis secretes three protein toxins: lethal factor (LF), edema factor (EF), and protective antigen (PA). EF and LF may circulate as free or PA-bound forms. Both free EF (EF) and PA-bound-EF (ETx) have adenylyl cyclase activity converting ATP to cAMP. We developed an adenylyl cyclase activity-based method for detecting and quantifying total EF (EF+ETx) in plasma. The three-step method includes magnetic immunocapture with monoclonal antibodies, reaction with ATP generating cAMP, and quantification of cAMP by isotope-dilution HPLC-MS/MS. Total EF was quantified from 5PL regression of cAMP vs ETx concentration. The detection limit was 20 fg/mL (225 zeptomoles/mL for the 89 kDa protein). Relative standard deviations for controls with 0.3, 6.0, and 90 pg/mL were 11.7-16.6% with 91.2-99.5% accuracy. The method demonstrated 100% specificity in 238 human serum/plasma samples collected from unexposed healthy individuals, and 100% sensitivity in samples from 3 human and 5 rhesus macaques with inhalation anthrax. Analysis of EF in the rhesus macaques showed that it was detected earlier post-exposure than B. anthracis by culture and PCR. Similar to LF, the kinetics of EF over the course of infection were triphasic, with an initial rise (phase-1), decline (phase-2), and final rapid rise (phase-3). EF levels were ~ 2-4 orders of magnitude lower than LF during phase-1 and phase-2 and only ~ 6-fold lower at death/euthanasia. Analysis of EF improves early diagnosis and adds to our understanding of anthrax toxemia throughout infection. The LF/EF ratio may also indicate the stage of infection and need for advanced treatments.


Asunto(s)
Carbunco/patología , Antígenos Bacterianos/sangre , Bacillus anthracis/patogenicidad , Toxinas Bacterianas/sangre , Cromatografía Líquida de Alta Presión/métodos , Infecciones del Sistema Respiratorio/patología , Espectrometría de Masas en Tándem/métodos , Toxemia/patología , Adenosina Trifosfato/metabolismo , Animales , Carbunco/sangre , Estudios de Casos y Controles , AMP Cíclico/biosíntesis , Progresión de la Enfermedad , Ensayo de Inmunoadsorción Enzimática , Humanos , Límite de Detección , Macaca mulatta , Reacción en Cadena de la Polimerasa , Infecciones del Sistema Respiratorio/sangre , Toxemia/sangre , Toxemia/microbiología
15.
Methods Mol Biol ; 1871: 295-311, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30276747

RESUMEN

Protein digestion coupled to liquid chromatography and tandem mass spectrometry (LC-MS/MS) detection enables multiplexed quantification of proteins in complex biological matrices. However, the reproducibility of enzymatic digestion of proteins to produce proteotypic target peptides is a major limiting factor of assay precision. Online digestion using immobilized trypsin addresses this problem through precise control of digestion conditions and time. Because online digestion is typically for a short time, the potential for peptide degradation, a major source of measurement bias, is significantly reduced. Online proteolysis requires minimal sample preparation and is easily coupled to LC-MS/MS systems, further reducing potential method variability. We describe herein a method optimized for the multiplexed quantification of several apolipoproteins in human serum using on-column digestion. We highlight key features of the method that enhance assay accuracy and precision. These include the use of value-assigned serum as calibrators and stable isotope-labeled (SIL) peptide analogs as internal standards. We also comment on practical aspects of column switching valve design, instrument maintenance, tandem mass spectrometry data acquisition, and data processing.


Asunto(s)
Cromatografía Liquida , Proteínas , Espectrometría de Masas en Tándem , Tripsina , Apolipoproteínas/análisis , Apolipoproteínas/química , Apolipoproteínas/metabolismo , Proteínas Sanguíneas/química , Cromatografía Líquida de Alta Presión , Cromatografía Liquida/métodos , Análisis de Datos , Enzimas Inmovilizadas , Humanos , Péptidos/química , Proteínas/análisis , Proteínas/química , Proteolisis , Programas Informáticos , Espectrometría de Masas en Tándem/métodos , Tripsina/química
16.
Diabetes ; 67(12): 2494-2506, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30213825

RESUMEN

In clinical trials, inhibition of cholesteryl ester transfer protein (CETP) raises HDL cholesterol levels but does not robustly improve cardiovascular outcomes. Approximately two-thirds of trial participants are obese. Lower plasma CETP activity is associated with increased cardiovascular risk in human studies, and protective aspects of CETP have been observed in mice fed a high-fat diet (HFD) with regard to metabolic outcomes. To define whether CETP inhibition has different effects depending on the presence of obesity, we performed short-term anacetrapib treatment in chow- and HFD-fed CETP transgenic mice. Anacetrapib raised HDL cholesterol and improved aspects of HDL functionality, including reverse cholesterol transport, and HDL's antioxidative capacity in HFD-fed mice was better than in chow-fed mice. Anacetrapib worsened the anti-inflammatory capacity of HDL in HFD-fed mice. The HDL proteome was markedly different with anacetrapib treatment in HFD- versus chow-fed mice. Despite benefits on HDL, anacetrapib led to liver triglyceride accumulation and insulin resistance in HFD-fed mice. Overall, our results support a physiologic importance of CETP in protecting from fatty liver and demonstrate context selectivity of CETP inhibition that might be important in obese subjects.


Asunto(s)
Proteínas de Transferencia de Ésteres de Colesterol/antagonistas & inhibidores , Proteínas de Transferencia de Ésteres de Colesterol/genética , HDL-Colesterol/sangre , Dieta Alta en Grasa , Hígado Graso/genética , Resistencia a la Insulina/fisiología , Animales , Anticolesterolemiantes/farmacología , Proteínas de Transferencia de Ésteres de Colesterol/metabolismo , Hígado Graso/metabolismo , Ratones , Ratones Transgénicos , Oxazolidinonas/farmacología
17.
Clin Chem ; 64(10): 1485-1495, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30087138

RESUMEN

BACKGROUND: Despite the usefulness of standard lipid parameters for cardiovascular disease risk assessment, undiagnosed residual risk remains high. Advanced lipoprotein testing (ALT) was developed to provide physicians with more predictive diagnostic tools. ALT methods separate and/or measure lipoproteins according to different parameters such as size, density, charge, or content, and equivalence of results across methods has not been demonstrated. METHODS: Through a split-sample study, 25 clinical specimens (CSs) were assayed in 10 laboratories before and after freezing using the major ALT methods for non-HDL particles (non-HDL-P) or apolipoprotein B-100 (apoB-100) measurements with the intent to assess their comparability in the current state of the art. RESULTS: The overall relative standard deviation (CV) of non-HDL-P and apoB-100 concentrations measured by electrospray differential mobility analysis, nuclear magnetic resonance, immunonephelometry, LC-MS/MS, and vertical autoprofile in the 25 frozen CSs was 14.1%. Within-method comparability was heterogeneous, and CV among 4 different LC-MS/MS methods was 11.4% for apoB-100. No significant effect of freezing and thawing was observed. CONCLUSIONS: This study demonstrates that ALT methods do not yet provide equivalent results for the measurement of non-HDL-P and apoB-100. The better agreement between methods harmonized to the WHO/IFCC reference material suggests that standardizing ALT methods by use of a common commutable calibrator will improve cross-platform comparability. This study provides further evidence that LC-MS/MS is the most suitable candidate reference measurement procedure to standardize apoB-100 measurement, as it would provide results with SI traceability. The absence of freezing and thawing effect suggests that frozen serum pools could be used as secondary reference materials.


Asunto(s)
Apolipoproteína B-100/sangre , Enfermedades Cardiovasculares/sangre , Técnicas de Laboratorio Clínico , Lipoproteínas LDL/sangre , Lipoproteínas VLDL/sangre , Calibración , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/normas , Humanos , Estándares de Referencia , Sensibilidad y Especificidad , Manejo de Especímenes
18.
PLoS One ; 13(4): e0194797, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29634782

RESUMEN

Lipoproteins are complex molecular assemblies that are key participants in the intricate cascade of extracellular lipid metabolism with important consequences in the formation of atherosclerotic lesions and the development of cardiovascular disease. Multiplexed mass spectrometry (MS) techniques have substantially improved the ability to characterize the composition of lipoproteins. However, these advanced MS techniques are limited by traditional pre-analytical fractionation techniques that compromise the structural integrity of lipoprotein particles during separation from serum or plasma. In this work, we applied a highly effective and gentle hydrodynamic size based fractionation technique, asymmetric flow field-flow fractionation (AF4), and integrated it into a comprehensive tandem mass spectrometry based workflow that was used for the measurement of apolipoproteins (apos A-I, A-II, A-IV, B, C-I, C-II, C-III and E), free cholesterol (FC), cholesterol esters (CE), triglycerides (TG), and phospholipids (PL) (phosphatidylcholine (PC), sphingomyelin (SM), phosphatidylethanolamine (PE), phosphatidylinositol (PI) and lysophosphatidylcholine (LPC)). Hydrodynamic size in each of 40 size fractions separated by AF4 was measured by dynamic light scattering. Measuring all major lipids and apolipoproteins in each size fraction and in the whole serum, using total of 0.1 ml, allowed the volumetric calculation of lipoprotein particle numbers and expression of composition in molar analyte per particle number ratios. Measurements in 110 serum samples showed substantive differences between size fractions of HDL and LDL. Lipoprotein composition within size fractions was expressed in molar ratios of analytes (A-I/A-II, C-II/C-I, C-II/C-III. E/C-III, FC/PL, SM/PL, PE/PL, and PI/PL), showing differences in sample categories with combinations of normal and high levels of Total-C and/or Total-TG. The agreement with previous studies indirectly validates the AF4-LC-MS/MS approach and demonstrates the potential of this workflow for characterization of lipoprotein composition in clinical studies using small volumes of archived frozen samples.


Asunto(s)
Apolipoproteínas/sangre , Cromatografía Liquida/métodos , Fraccionamiento de Campo-Flujo/métodos , Lípidos/sangre , Lipoproteínas/sangre , Espectrometría de Masas en Tándem/métodos , Apolipoproteína A-I/metabolismo , Apolipoproteína B-100/metabolismo , Análisis Químico de la Sangre/métodos , Calibración , Colesterol/química , Humanos , Luz , Modelos Estadísticos , Tamaño de la Partícula , Control de Calidad , Dispersión de Radiación , Flujo de Trabajo
19.
J Lipid Res ; 58(12): 2275-2288, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28986437

RESUMEN

As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement.


Asunto(s)
Benchmarking , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Lípidos/sangre , Humanos , Cooperación Internacional , Metabolismo de los Lípidos/fisiología , Lípidos/normas , Variaciones Dependientes del Observador , Estándares de Referencia , Reproducibilidad de los Resultados
20.
J Am Soc Mass Spectrom ; 28(11): 2319-2329, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28801822

RESUMEN

We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 µL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. Graphical Abstract ᅟ.


Asunto(s)
Colesterol/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Triglicéridos/sangre , Ésteres del Colesterol/sangre , Humanos , Hidrólisis , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...